Request Calibration Where to Buy Region: Global ▾
Application Note

Hexagon CMM Probes, Test Equipment, and Megger Testing: A Quality Manager's FAQ

Posted on 2026-11-06 by Luc Moreau

I review 200+ pieces of test and measurement gear every year before it touches a production floor. These are the questions I actually get asked—by junior engineers, by procurement, and by people who just inherited a calibration budget and have no idea where to start.

Where is Hexagon's official website—and does it actually matter?

For Hexagon, that's hexagon.com. And yes, it matters more than most people think.

Look, I'm not going to tell you every third-party reseller is bad. That's not true. But in early 2024, we ordered what were advertised as Hexagon CMM probe tips from a marketplace seller at 15% below list price. Saved about $340. Three probes failed repeatability checks—0.8 μm drift on a 2 μm spec, which didn't show up until we ran a calibration sphere test. We scrapped the batch, reordered direct, ate the downtime. Net loss: roughly $2,100.

The official site also has a serial number verification page. Takes 30 seconds. Skipping it cost us two weeks.

Are Hexagon CMM probes interchangeable across models?

No. And this one bit me personally.

I assumed "same specifications" meant identical results across vendors. Didn't verify. Turned out each had slightly different interpretations of stylus thread and effective working length. Hexagon's probing range covers touch-trigger and scanning applications, with M2, M3, and M5 threads, ruby and silicon nitride contacts, and very different stiffness profiles.

Putting a scanning-spec probe on a touch-trigger head—or the reverse—doesn't just give you worse numbers. It can flex enough to damage the probe head. We spent $6,000 learning that. Per ISO 10360-1, probe configuration feeds directly into the measurement uncertainty budget. Don't treat tips as universal.

How do I buy test equipment without getting burned?

Three rules, and I'm stubborn about all of them.

One: verify the seller's authorization status. Not "family business since 1987"—authorization. Two: demand calibration certificates at the time of order, not after. Three: never accept "probably ships Friday" as a delivery estimate.

The "budget vendor" choice looks smart until you need service support. We once bought a batch of clamp meters from a discount channel to save roughly $1,900. Four failed within the first month. The warranty required shipping to a third-party repair depot with a six-week turnaround. Replacing them properly cost more than the original premium quote. That's the penny-wise pattern, and it repeats.

What is a 116 true RMS multimeter, and do I actually need one?

"116" usually refers to a specific model in the Fluke 116 family—an HVAC-oriented true RMS meter with temperature and microamp measurement built in. But the more important question is whether True RMS matters for your work at all.

Short answer: it depends on what you're measuring. True RMS meters give accurate readings on distorted, non-sinusoidal waveforms—variable frequency drives, switching power supplies, HVAC inverter outputs. A standard averaging meter reads low on those. If you're only checking clean 60 Hz mains, a basic meter is fine.

For safety, check that the meter meets IEC 61010-1:2010 for the category rating where you'll use it. CAT III or CAT IV ratings matter more than the brand name on the front.

How do you use a megger insulation tester without wrecking anything?

Process, in order. Skip a step and you'll either get bad readings or a very expensive bang.

  1. De-energize and lock out the circuit. Verify with a known-good voltage tester—not just the panel indicator.
  2. Disconnect sensitive electronics from the circuit. Megger test voltages (250V, 500V, 1000V) will destroy them.
  3. Ground and discharge the conductor for a few minutes. Capacitance holds charge.
  4. Connect test leads: line to conductor, earth to ground. Confirm the tester's own leads are rated for the test voltage.
  5. Select test voltage per the equipment's insulation rating—typically 500V for 480V systems, 1000V for medium-voltage cable, per manufacturer specs.
  6. Apply for the standard duration (usually 60 seconds for a spot reading). Note the resistance and the dielectric absorption ratio if you're tracking trends.
  7. Discharge again before disconnecting. That step gets skipped constantly, and it's the one that hurts.

I watched a tech skip step two once. Blew the control board on a $3,800 drive. The tester worked perfectly—right up until it didn't matter.

Is calibration worth the lead time, or can I skip it once?

Here's the thing about calibration: the certificate isn't the product. The confidence is.

Per ISO/IEC 17025:2017, accredited calibration gives you traceability to national standards—for us, NIST. That traceability is what your customer's auditor will ask for, and "we calibrated it in-house" rarely survives that conversation.

On lead time: yes, calibration adds days. In Q3 2024, we had a rush job, skipped pre-ship calibration on a batch of pressure gauges to hit a deadline, and shipped on time. Two units out of twenty read outside tolerance on arrival. That quality issue cost us a $22,000 redo and delayed our launch by three weeks. The calibration would've added four days.

When is rush delivery actually worth paying for?

More often than people admit, honestly. But not always.

In March 2024, we paid $400 extra for rush delivery on a set of reference standards. The alternative was missing a customer acceptance event worth about $15,000. That one's easy math.

The harder question is what "rush" actually buys you. If the vendor says "we'll try," that's not rush—that's hope. After getting burned twice by "probably on time" promises, we now budget only for guaranteed delivery windows, in writing, with penalties attached. Uncertain cheap is more expensive than certain premium.

There's something satisfying about a rush order that lands on time and correct. After all the coordination and stress, seeing the delivery note match the spec sheet—that's the payoff. But I only feel that way because we stopped paying for vague promises.

Leave a technical note